SIL and PL | History and Distinction - Pepperl+Fuchs

文章推薦指數: 80 %
投票人數:10人

Speaking of ways to rate systems for use in today's safety applications, the acronyms SIL (safety integrity level), PL (performance level), and SILCL (SIL ... Beginswith... Contains... ServicelineIndustrialSensors ServicelineExplosionProtection Products IndustrialSensors ProximitySensors PhotoelectricSensors IndustrialVision UltrasonicSensors RotaryEncoders PositioningSystems InclinationandAccelerationSensors VibrationMonitoring IndustrialCommunication IdentificationSystems DisplaysandSignalProcessing Connectivity Accessories Software ExplosionProtection IntrinsicSafetyBarriers SignalConditioners FieldConnexEthernet-APLandFieldbusInfrastructure RemoteI/OSystems HARTInterfaceSolutions SurgeProtection WirelessSolutions IntrinsicallySafeMobileDevices HMISystems ElectricalExplosionProtectionEquipment Purge+PressurizationSystems PowerSupplies LevelMeasurement Software QuickandEasy Useourselectiontoolandquicklyfindtherightproductforyourapplication. ProductSelector GetpreparedforthechallengesofIndustry4.0—withsmartsolutionsfromPepperl+Fuchs. GetpreparedforthechallengesofIndustry4.0—withsmartsolutionsfromPepperl+Fuchs. Markets IndustrialSensors Applications Machine+PlantEngineering AutomotiveIndustry MobileEquipment RenewableEnergy MaterialHandling Print+PaperIndustry PackagingIndustry ElectronicsIndustry ProcessEquipment EntranceAutomation ExplosionProtection Applications Offshore+Marine Oil+Gas ChemicalIndustry Pharmaceutics PowerIndustries Water+WasteWater Services+Support CustomerService CyberSecurityInformationandReporting EngineeringData Training+Seminars DownloadTechnicalDocumentsViewAllSubsidiaries+Distributors CustomizedSolutions IndustrialSensors StructureofaPepperl+FuchsTypeCode LiteratureforIndustrialSensors PressReleasesTechnologies ExplosionProtection AskanExpert ProjectManagement ControlSystemSolutions LiteratureforExplosionProtection ServiceLevelAgreementsforecominstruments ReleaseNotesforPepperl+FuchsThinClientSoftware PressReleasesTechnologies ContactUs Careers —ThePepperl+FuchsMagazine AboutUs What'sNew? Blog CountrySelect English Deutsch Español HomeExplosionProtectionTechnologiesFunctionalSafety—SafetyIntegrityLevel(SIL)andPerformanceLevel(PL)SafetyIntegrityLevel(SIL)andPerformanceLevel(PL)—HistoryandDistinction Speakingofwaystoratesystemsforuseintoday’ssafetyapplications,theacronymsSIL(safetyintegritylevel),PL(performancelevel),andSILCL(SILclaimlevel)cometomind.Inthefirstplace,thisonlyseemstomakethetopicmorecomplicatedtocomprehend,butultimatelythisdistinctioncanbeunderstoodwhentheirevolutionandtheirbackgroundareilluminated. IEC61508andIEC61511—DrivenbyChemicalIndustries ThedevelopmentofthestandardsIEC61508andIEC61511forfunctionalsafetywasencouragedandsupportedmainlybythechemicalindustry.Astraditionalstandardswerebasingsafetyonspecialsystemarchitecturesorregulartesting,theapplicationofsafetyPLCswasnotpossibledirectly.Programmeddevicescaninheritdeficienciespopularlyknownas‘bugs’,whichhavetheproblematicfeaturethatinredundanciesasimultaneousfailurecannotreallybeexcluded. Theideawastobasesafetystatementsontheprobabilityforreliablefunctionincaseanydemandforasafereactionwasgiven.Withthedeterminationofcertainrulesforastructuredapproachindevelopmentandtestingofhardwareandsoftware,thestandardsprovidedasystemthathasproventobesuitableforsafetyapplicationsthroughouttheyears. CloseRelationsBetweenSafetyStandards However,whilethechemicalindustrymostlyfacesrisksthatneedasafetyrelatedreactioneveryfewyearsorevenlessfrequent,thesafetysystemsinmachinerycanbedemandedveryoftenorcontinuallywhenthemachineisused.ThisiswhyISO13849-1wasdevelopedbasedonthementionedtraditionalstandardswhileadditionallyopeningthewayfortheuseofsafetyPLCsbyincludingtheprobabilisticapproach.Withthisstandard,thenecessitiesevolvingfromthemachinerydirectivewerecoveredaswell. Asthelastparagraphalreadyshows,therearecloserelationshipsbetweenthementionedstandards.AndsotherearenotonlytheacronymsSILfromtheIEC61508andPLfromtheISO13849buttherealsoisaSILCLdefinedinIEC62061whichisalsousableinthemachineryworldbutclosertotheSILworldwithprogrammabledevices. PlantSafetyandMachinerySafety—TwoSidesofOneCoin Machinerydirective2006/42/EGregulatessafetyrequirementsonmachineryandinstallationsthatarebroughtontothemarketintheEuropeanUnion.Whichproductsareunderthedirectiveispreciselynamed.Incomparisontothepreviousversion,thenewdirectiveislayingmorestressonanextensiveriskassessmentofthemachinery,whichincludesanextensiveriskanalysis.Atthesametimeinfacilitatesamethodforasimplifiedconformityassessmentformachinerywhenusingharmonizedstandards. ThesestandardsincludethementionedENISO13849seriesandtheENIEC62061,whichregulateestablishingthefunctionalsafetyofsafetyrelatedandprogrammableelectroniccontrolsystems. BothofthesestandardsarecloselylinkedtothestandardsENIEC61508forfunctionalsafety,whichgiveaframeworkincludingnecessitiesforsafetymanagementlikedefinitionofprocesses,regulationofresponsibilitiesandorganizationalmeasures.ThisiswhytheENIEC61508standardsarealsocitedwhenthestandardsforsafetyfunctionsunderthemachinerydirectivedefinehigherrankedsafetyfunctions.Inconjunctionwithfurtherspecificsafetystandards,anetworkevolvesthathasinfluenceonallpartsofmachine andplantsafety.Aimofallthesemeasuresistheimplementationofsuitablesafetyfunctionsforthemachineandplantsafetysector. MoreInformationonFunctionalSafety Pepperl+Fuchsprovidessolutionsforbothsidesofthiscoinandoffersamanifoldofdevicesthatmightbejustwhatyouneedforyourapplication.Pleaseuseourselectiontooltofindthesuitablesafetydevicesordigdeeperintosafetyknowledgebyclickingthelinksbelow. SafetyProductSelectorSafetyIntegrityLevel(SIL)PerformanceLevel(PL) GoTo IndustrialSensors ExplosionProtection QuickLinks News ServiceLevelAgreementsforecominstruments WheretoBuy BrowseLiterature Technologies ControlSystemSolutions DownloadTechnicalDocuments PressReleases InternationalTradeShows VisittheFunctionalSafetyHub SeveralhundredproductswithaSIL/PLassessment,freetools,andbrochuresinoneplace: the"FunctionalSafetyHub"isyourstartingpointwhenyouhavetoimplementsafetyfunctions. Approvals+Certificates CertificationFunctionalSafetyManagement(PDF,0.1MB) Pepperl+FuchsSELilienthalstraße20068307MannheimGermany [email protected]  +49621776-0 HomeIndustrialSensorsExplosionProtectionProductsMarketsContactUs AboutUsCareersWhat'sNew? Amplify SelectCountry Sitemap LegalNoticeDisclaimer PrivacyPolicy ©2022AllRightsReserved. Pepperl+Fuchsisaleadingdeveloperandmanufacturerofelectronicsensorsandcomponentsfortheglobalautomationmarket.Continuousinnovation,enduringquality,andsteadygrowthhavebeenthefoundationofoursuccessformorethan70years.Pepperl+Fuchsemploys6,300peopleworldwideandhasmanufacturingfacilitiesinGermany,USA,Singapore,Hungary,IndonesiaandVietnam,mostofthemISO9001certified.



請為這篇文章評分?